Informix - Problem description
Problem IT35757 | Status: Closed |
A BLOB IS INSERTED INTO THE WRONG SMART BLOB SPACE WHEN USING PREPAREDSTATEMENT.GETPARAMETERMETADATA() | |
product: | |
IBM CSDK / 5724C2381 / 450 - CSDK 4.50 | |
Problem description: | |
When using PreparedStatement.getParameterMetaData(), a smart blob will be inserted into the wrong smart blob space. It will be inserted into the default smart blob space that is specified in the onconfig file regardless of what smart blob space is specified in a PUT statement. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of Informix JDBC prior to 4.50.JC5. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description. * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix JDBC 4.50.JC6 (when available). * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
**************************************************************** * USERS AFFECTED: * * Users of Informix JDBC prior to 4.50.JC5. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description. * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix JDBC 4.50.JC6 (when available). * **************************************************************** | |
Comment | |
Fixed in Informix JDBC 4.50.JC6. | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 01.02.2021 23.04.2021 23.04.2021 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) |