Informix - Problem description
Problem IT37050 | Status: Closed |
SELECT FROM SYSMASTER SYSSQLTRACE FAILS WITH ERROR -1223 | |
product: | |
INFORMIX SERVER / 5725A3900 / E10 - | |
Problem description: | |
select * from syssqltrace returns error 1223: Value will not fit in a FLOAT. the reason is an invalid entry in syssqltrace.sql_rowspersec, which has an "inf" value and is a float column. The inf values are seen most often with inserts, but occasionally also with execute procedure and deletes, but not with selects. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC15 and 14.10.xC7. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC15 or 14.10.xC7. * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC15 and 14.10.xC7. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC15 or 14.10.xC7. * **************************************************************** | |
Comment | |
Fixed in Informix Server 12.10.xC15 and 14.10.xC7. | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 28.05.2021 01.11.2021 01.11.2021 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) |