Informix - Problem description

Problem IT37128 Status: Closed

EXCESSIVE READS ON SYSPROCAUTH IF PROCEDURE DOES NOT HAVE 'PUBLIC' EXECUTE
PERMISSION OR USER DOES NOT HAVE DBA PRIVILEGE

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
A session will maintain a local cache of stored procedure ids
for which the execute or grant with execute permissions are
available. This cache only lists those procedures for which
public execute permissions are granted meaning that non-dba
users will need to query the sysprocauth system catalogue table
to determine the execute permission for other procedures. This
can result in a high number of reads against that table with a
loss of performance.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
* available).                                                  *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
* available).                                                  *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC15 and 14.10.xC7.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
04.06.2021
25.08.2021
25.08.2021
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)