Informix - Problem description

Problem IT40284 Status: Closed

SECONDARY SERVER BACKLOG DUE TO MISSING READ-AHEAD RECOVERING CLR RECORDS

product:
INFORMIX SERVER / 5725A3900 / E10 - 
Problem description:
When log recovery rolls forward a rollback found in the logical
logs, it has to access old log records pointed to by CLR records
as well as data/index pages referenced by those old log records
Old log records' log. log pages have to be read from disk into
bufferpool, yet without any read-ahead, so since this old log
record lookup is performed by the log scanner (master replay
thread), it can become a significant bottleneck for log
recovery.
In case the rollback is for a transaction whose rollforward
phase has already been seen by this log recovery, the data and
index pages had a fairly good chance of still residing in
bufferpools; if, on the other hand, the rollback is for a
transaction that occurred well before the fast/log recovery
starting point, it would also suffer from missing read-ahead for
those pages.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 14.10.FC10.                *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 14.10.FC10.                       *
****************************************************************
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 14.10.FC10.                *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 14.10.FC10.                       *
****************************************************************
Comment
Fixed in Informix Server 14.10.FC10.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
15.03.2022
22.02.2023
22.02.2023
Problem solved at the following versions (IBM BugInfos)