Informix - Problem description
| Problem IT41880 | Status: Closed |
SET ENVIRONMENT IFX_FOLDVIEW IS NOT SPECIFIC TO A SESSION | |
| product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
| Problem description: | |
Consider an instance where IFX_FOLDVIEW has been set to 0 in the
onconfig.
If a user runs the following SQL command to turn on this
feature:
set environment IFX_FOLDVIEW "1";
then the feature is turned on for the whole instance, not just
that user's session.
In essence, it is working just like the onmode command:
$ onmode -wm IFX_FOLDVIEW=1 | |
| Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC16 and 14.10.xC10. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC16 or 14.10.xC10. * **************************************************************** | |
| Local Fix: | |
| Solution | |
| Workaround | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC16 and 14.10.xC10. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC16 or 14.10.xC10. * **************************************************************** | |
| Comment | |
Fixed in Informix Server 12.10.xC16 and 14.10.xC10. | |
| Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 26.08.2022 15.05.2023 15.05.2023 |
| Problem solved at the following versions (IBM BugInfos) | |
| Problem solved according to the fixlist(s) of the following version(s) | |