Informix - Problem description
Problem IT41932 | Status: Closed |
THE INFORMIX HQ AGENT DOES NOT CHANGE THE FREQUENCY OF RUNNING IF SERVER IS IN QUIESCENT MODE | |
product: | |
INFORMIX SERVER / 5725A3900 / E10 - | |
Problem description: | |
f the server is in quiescent mode, the defined sensors will still run with their definied frequency. This will lead to two effects a) lots and lots of connections errors will be reported on the server and b) the hqagent log will be spammed with masses of error messages. 2022-08-10 13:23:17 [InformixHQ-Agent-session_stats] INFO com.informix.hq.agent.metrics.sql.SqlMetric - Skipping SQL metric: Session Statistics. Informix server is not online. 2022-08-10 13:23:32 [InformixHQ-Agent-session_stats] INFO com.informix.hq.agent.metrics.sql.SqlMetric - Skipping SQL metric: Session Statistics. Informix server is not online. 2022-08-10 13:23:47 [InformixHQ-Agent-session_stats] INFO com.informix.hq.agent.metrics.sql.SqlMetric - Skipping SQL metric: Session Statistics. Informix server is not online. now having a server is quiescent mode is valid, and while the agent need to check the state, of the server periodically, it should not do it for all the sensors individually. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 14.10.xC10. * * Users of InformixHQ prior to 2.3.0. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 14.10.xC10. * * Update to InformixHQ 2.3.0. * **************************************************************** This is a partial fix to address the repeated messages of sensors. | |
Local Fix: | |
Solution | |
Workaround | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 14.10.xC10. * * Users of InformixHQ prior to 2.3.0. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 14.10.xC10. * * Update to InformixHQ 2.3.0. * **************************************************************** This is a partial fix to address the repeated messages of sensors. | |
Comment | |
Fixed in Informix Server 14.10.xC10. Fixed in InformixHQ 2.3.0. | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 02.09.2022 07.03.2023 07.03.2023 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) |