Informix - Problem description
Problem IT45991 | Status: Closed |
TK_NEXT_EXECUTION COLUMN IS NOT ALWAYS ADVANCED IN CASE THE AUS_REFRESH TASK RUNS IN AN ERROR | |
product: | |
INFORMIX SERVER / 5725A3900 / E10 - | |
Problem description: | |
When the aus_refresher task is running in an error situation e.g the aus_command tables are not exists, the column tk_next_execution in ph_task is not advanced to the next execution time. This may lead to a catch22 situation since the aus_refresh next execution is older than the current time of the next aus_eval execution and this lead the evaluator to stop working even this thread is always advancing the value. Once the refresher is out of sync in the tk_next_execution only a manual update may "repair" the situation. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 14.10.xC11. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 14.10.xC11. * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 14.10.xC11. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 14.10.xC11. * **************************************************************** | |
Comment | |
Fixed in Informix Server 14.10.xC11. | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 22.04.2024 19.07.2024 24.09.2024 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) |