Informix - Problembeschreibung

Problem IT27027 Status: Geschlossen

EXECUTING CONVERSION/REVERSION SCRIPTS CAN FAIL DUE TO BLANKS
ININFORMIXDIR

Produkt:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problembeschreibung:
The way conversion scripts are called during version upgrade
(conversion) or reversion can lead to failure like this:

10/09/18 11:46:11  Conv/Rev: External script failure exec "set
IFX_CRV_CONNECTION_ONLY=14488 & C:Program FilesIBM Informix
Software Bundleetcconvconvtestblade1210.bat 11.70.xC3 12.10"
status 1 cmd_errno 0
10/09/18 11:46:11  Conv/rev: blade conversion test failed. See
$INFORMIXDIR/etc/conv/convtestblade1210.out

... with the diagnostic .out file not even existing.

Reason is the path-to-command-file isn't quoted, so any blank in
e.g. the path would cause the path's first part, up to the first
blank, to be taken as the command to be executed.  As this
clearly would never lead to the actual script being executed,
the .out file cannot exist as it would be created by the script.

While this is a typical Windows Problem (when having Informix
installed in default directory, s. above), in theory this also
could occur on any other platform (or file system) allowing
blanks in file names.
Problem-Zusammenfassung:
****************************************************************
* USERS AFFECTED:                                              *
* Users of IDS prior to 12.10.xC13.                            *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* Executing conversion/reversion scripts can fail due to       *
* blanks in INFORMIXDIR.                                       *
****************************************************************
* RECOMMENDATION:                                              *
****************************************************************
Local-Fix:
First go back to old version's state, using new version's
onrestorept utility or old version's restore, then reinstall new
version into a directory with no blanks in name, then retry
upgrade.
Lösung
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
19.11.2018
26.09.2019
26.09.2019
Problem behoben ab folgender Versionen (IBM BugInfos)
12.10.xC13
Problem behoben lt. FixList in der Version
Informix EditionenInformix Editionen
Informix Editionen
DokumentationDokumentation
Dokumentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download