DB2 - Problembeschreibung
Problem IT25927 | Status: Geschlossen |
PADIAGLOGCOLL::PARSEFILTERPARMS SHOWS UP IN DB2DIAG.LOG FREQUENTLY. | |
Produkt: | |
DB2 FOR LUW / DB2FORLUW / B10 - DB2 | |
Problembeschreibung: | |
PADiagLogColl::parseFilterParms shows up in db2diag.log with message "START TIMESTAMP and END TIMESTAMP" as following sample shows when application invoke PD_GET_DIAG_HIST() table function with invalid parameters where starttime > endtime, but no error return to the application. 2018-03-30-17.51.04.291464+540 E559724A1376 LEVEL: Error PID : 12345678 TID : 1234 PROC : db2sysc 0 INSTANCE: db2inst1 NODE : 000 DB : SAMPLE APPHDL : 0-32 APPID: *LOCAL.e111q1n.180330085039 AUTHID : XXXXX HOSTNAME: EDUID : 3343 EDUNAME: db2agent (SAMPLE) 0 FUNCTION: DB2 UDB, RAS/PD component, PADiagLogColl::parseFilterParms, probe:20 MESSAGE : ECF=0x9000000C=-1879048180=ECF_INVALID_PARAMETER Invalid parameter DATA #1 : String, 42 bytes START TIMESTAMP greater than END TIMESTAMP DATA #2 : SQLCA, PD_DB2_TYPE_SQLCA, 136 bytes 0x0000000110FDCEC0 : 0000 0000 0000 0000 0000 0000 FFFF F810 ................ 0x0000000110FDCED0 : 0021 5354 4152 5420 5449 4D45 5354 414D .!START TIMESTAM 0x0000000110FDCEE0 : 5020 616E 6420 454E 4420 5449 4D45 5354 P and END TIMEST 0x0000000110FDCEF0 : 414D 5000 0000 0000 0000 0000 0000 0000 AMP............. 0x0000000110FDCF00 : 0000 0000 0000 0000 0000 0000 0000 0000 ................ 0x0000000110FDCF10 : 0000 0000 0000 0000 0000 0000 0000 0000 ................ 0x0000000110FDCF20 : 0000 0000 0000 0000 0000 0000 0000 0000 ................ 0x0000000110FDCF30 : 0000 0000 0000 0000 0000 0000 0000 0000 ................ 0x0000000110FDCF40 : 0000 0000 0000 0000 ........ 2018-03-30-17.51.04.292095+540 I561101A626 LEVEL: Warning PID : 12345678 TID : 1234 PROC : db2sysc 0 INSTANCE: e111q1n NODE : 000 DB : SAMPLE APPHDL : 0-32 APPID: *LOCAL.e111q1n.180330085039 AUTHID : XXXX HOSTNAME: EDUID : 3343 EDUNAME: db2agent (SAMPLE) 0 FUNCTION: DB2 UDB, WLM, sqlrwGetPDDiagHist_v10fp3, probe:200 MESSAGE : ECF=0x9000000C=-1879048180=ECF_INVALID_PARAMETER Invalid parameter DATA #1 : String, 75 bytes Error initializing the diag log collector. Not able to access the diag log. Local bypass: Make sure starttime is less than endtime when invoke PD_GET_DIAG_HIST() | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Db2 11.1 Mod 4 Fixpack 4 or higher * **************************************************************** | |
Local-Fix: | |
Lösung | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 09.08.2018 27.11.2018 27.11.2018 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
Problem behoben lt. FixList in der Version |