ERROR -5030 WHEN CONNECTING TO A SPWDCSM PASSWORD ENCRYPTED SERVER | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / B70 - IDS 11.70 | |
Problembeschreibung: | |
Opening a JDBC connection to a server configured with simple password encryption may fail with error -5030. A second attempt with the same details will connect successful. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Users of IDS 11.70.xC9 and earlier versions. * **************************************************************** * PROBLEM DESCRIPTION: * * Opening a JDBC connection to a server configured with simple * * password encryption may fail with error -5030. * * A second attempt with the same details will connect * * successful. * **************************************************************** * RECOMMENDATION: * **************************************************************** | |
Local-Fix: | |
Lösung | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 26.12.2018 30.10.2019 30.10.2019 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
11.70.xC10 | |