Informix - Problembeschreibung
Problem IC57311 | Status: Geschlossen |
PAGE CLEANERS SET TO 128 GIVES " LOGICAL LOG LAYOUT MAY CAUSE ONLINE TO GET INTO LOCKED STATE" ERROR MESSAGE | |
Produkt: | |
IBM IDS ENTRP E / 5724L2304 / B15 - IDS 11.50 | |
Problembeschreibung: | |
When the configuration parameter CLEANERS is set to 128, the following error message is written to the online.log when Informix Dynamic Server is started up / restarted WARNING! Logical log layout may cause Dynamic Server to get into a locked state. Recommended smallest logical log size is 16 times maximum concurrent user threads. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All Users * **************************************************************** * PROBLEM DESCRIPTION: * * If onconfig parameter "CLEANERS " is set to 128. an unwanted * * warning message is printed to online.log. * **************************************************************** * RECOMMENDATION: * * Upgrade to IDS 11.50.xC5 and above. * **************************************************************** | |
Local-Fix: | |
Set CLEANERS between 1 to 127 | |
Lösung | |
This problem was first fixed in IDS 11.50xC2 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 18.07.2008 09.09.2009 09.09.2009 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
11.50.xC2, 11.50.xC5 | |
Problem behoben lt. FixList in der Version | |
11.50.xC2 |