Informix - Problembeschreibung
Problem IC61119 | Status: Geschlossen |
ENABLE FILETOBLOB/FILETOCLOB TO READ FROM NAMED PIPES | |
Produkt: | |
IBM IDS ENTRP E / 5724L2304 / B15 - IDS 11.50 | |
Problembeschreibung: | |
The FILETOBLOB/FILETOCLOB functions are not able to read fom named pipes. The LO handle is created but the blob/clob object has size=0. These functions should be able to read data from named pipes and pass it to a smart large object. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * IDS 7.31 users and above * **************************************************************** * PROBLEM DESCRIPTION: * * In filetoclob()/filetoblob(), if the named pipe is used as a * * client file to load the smart blob data, an empty smart blob * * object is created. * **************************************************************** * RECOMMENDATION: * * Upgrade to IDS 11.50.xC5 or above. * **************************************************************** | |
Local-Fix: | |
Lösung | |
Problem first fixed in IDS 11.50.xC5 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 13.05.2009 19.01.2010 19.01.2010 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
11.50.xC5 | |
Problem behoben lt. FixList in der Version | |
11.50.xC5 |