Informix - Problembeschreibung
Problem IT07094 | Status: Geschlossen |
ENTERPRISE REPLICATION HANG POSSIBLE IN DATASYNC APPLY THREAD (RQMDECREMENTUSE -> MT_SPIN_LOCK_WAIT) | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
Using 12.10.FC4 an identical ER target hang has been observed repeatedly, with one of the CDRD_* threads permanently 'running' in following stack: __fd_poll mt_spin_lock_wait() rqmDecrementUse() rqmUpdateHandleHelper() rqmGetTxnByStamp() rmiGetNextPendingTxn() rmNextMsg() dsiResolverThread() cdrTrampolineThread() th_init_initgls() startup() | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC5 * **************************************************************** | |
Local-Fix: | |
Lösung | |
Problem Fixed In IBM Informix Server 12.10.xC5 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 11.02.2015 16.10.2015 16.10.2015 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC5 | |
Problem behoben lt. FixList in der Version | |
12.10.xC5 | |
12.10.xC5.W1 |