Informix - Problembeschreibung
Problem IT08049 | Status: Geschlossen |
IT IS NOT DOCUMENTED THAT IPLOAD AND ONPERF REQUIRE INFORMIXBROW SER ENVIRONMENT VARIABLE SET IN ORDER TO VIEW THE HELP TOPICS | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
Currently there is no place in our documentation where INFORMIXBROWSER environment variable is mentioned. However it is required to be set in order to see ipload or onperf documentation if GUI help button is pressed. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * Informix 11.70, 12.10 * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * See Problem Conclusion * **************************************************************** | |
Local-Fix: | |
Lösung | |
To view the online help for the ipload and onperf utilities, set the INFORMIXDIRBROWSER environment variable to 1. | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 31.03.2015 30.12.2015 30.12.2015 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
Problem behoben lt. FixList in der Version | |
12.10.xC6 |