Informix - Problembeschreibung
Problem IT09043 | Status: Geschlossen |
ENGINE THROWS -392 ERROR ON A JOIN WHEN EXECUTED WITHIN A 4GL APPLICATION | |
Produkt: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problembeschreibung: | |
A 4GL application that ran successfully with IDS 12.10.FC4 receives a -392 error from the database server when run with IDS 12.10.FC5. -392 System error - unexpected null pointer encountered. | |
Problem-Zusammenfassung: | |
**************************************************************** * USERS AFFECTED: * * All users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC6 * **************************************************************** | |
Local-Fix: | |
Lösung | |
Problem Fixed In IBM Informix Server 12.10.xC6 | |
Workaround | |
keiner bekannt / siehe Local-Fix | |
Weitere Daten | |
Datum - Problem gemeldet : Datum - Problem geschlossen : Datum - der letzten Änderung: | 21.05.2015 30.12.2015 30.12.2015 |
Problem behoben ab folgender Versionen (IBM BugInfos) | |
12.10.xC6 | |
Problem behoben lt. FixList in der Version | |
12.10.xC6 |