DB2 - Problembeschreibung

Problem IT25628 Status: Geschlossen

WIN32 ONLY: DB2LEVEL GIVES SQL1022C IF INSTANCE NAME IS LONGER THAN 7
BYTES.

Produkt:
DB2 FOR LUW / DB2FORLUW / B10 - DB2
Problembeschreibung:
Win32 only: db2level gives SQL1022C if instance name is longer
than 7 bytes.
This steps illustrates how this problem happens.

1. Install Data Server Client 32-bit.
2. Create an instance named 8 bytes.
C:>db2icrt DB123456

3. Switch to the instance
C:>set DB2INSTANCE=DB123456

4. Run db2level.
C:>db2level
SQL1022C There is not enough memory available to process the
command.

CLP does not return errors, but some Db2 commands may fail.
Problem-Zusammenfassung:
****************************************************************
* USERS AFFECTED:                                              *
* ALL                                                          *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Db2 11.1 Mod 4 Fixpack 5 or higher                *
****************************************************************
Local-Fix:
Use instance name shorter than 8 bytes.
Lösung
Workaround
keiner bekannt / siehe Local-Fix
Weitere Daten
Datum - Problem gemeldet    :
Datum - Problem geschlossen :
Datum - der letzten Änderung:
10.07.2018
16.01.2020
16.01.2020
Problem behoben ab folgender Versionen (IBM BugInfos)
Problem behoben lt. FixList in der Version