DB2 - Problem description
Problem IT18145 | Status: Closed |
UPDATING SOFTMAX ON STANDBY DOESN'T TAKE EFFECT | |
product: | |
DB2 FOR LUW / DB2FORLUW / 970 - DB2 | |
Problem description: | |
Updating db cfg softmax for a standby database doesn't take effect even after restarting the database, "db2pd -d -dirty" shows "Current Softmax" is not changed. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * ALL * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to the latest fixpack of DB2 V10.1, V10.5 or V11.1. * **************************************************************** | |
Local Fix: | |
Plan for a takeover, after a takeover, the new softmax will take effect. | |
Solution | |
Workaround | |
not known / see Local fix | |
BUG-Tracking | |
forerunner : follow-up : IT18328 IT18483 IT18931 | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 28.11.2016 01.03.2017 01.03.2017 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) |