DB2 - Problem description

Problem IT25927 Status: Closed

PADIAGLOGCOLL::PARSEFILTERPARMS SHOWS UP IN DB2DIAG.LOG FREQUENTLY.

product:
DB2 FOR LUW / DB2FORLUW / B10 - DB2
Problem description:
PADiagLogColl::parseFilterParms shows up in db2diag.log with
message "START TIMESTAMP and END TIMESTAMP" as following sample
shows when application invoke PD_GET_DIAG_HIST() table function
with invalid parameters where starttime > endtime, but no error
return to the application.


2018-03-30-17.51.04.291464+540 E559724A1376         LEVEL: Error
PID     : 12345678             TID : 1234           PROC :
db2sysc 0
INSTANCE: db2inst1             NODE : 000           DB   :
SAMPLE
APPHDL  : 0-32                 APPID:
*LOCAL.e111q1n.180330085039
AUTHID  : XXXXX              HOSTNAME: 
EDUID   : 3343                 EDUNAME: db2agent (SAMPLE) 0
FUNCTION: DB2 UDB, RAS/PD component,
PADiagLogColl::parseFilterParms, probe:20
MESSAGE : ECF=0x9000000C=-1879048180=ECF_INVALID_PARAMETER
          Invalid parameter
DATA #1 : String, 42 bytes
START TIMESTAMP greater than END TIMESTAMP
DATA #2 : SQLCA, PD_DB2_TYPE_SQLCA, 136 bytes
0x0000000110FDCEC0 : 0000 0000 0000 0000 0000 0000 FFFF F810
................
0x0000000110FDCED0 : 0021 5354 4152 5420 5449 4D45 5354 414D
.!START TIMESTAM
0x0000000110FDCEE0 : 5020 616E 6420 454E 4420 5449 4D45 5354
P and END TIMEST
0x0000000110FDCEF0 : 414D 5000 0000 0000 0000 0000 0000 0000
AMP.............
0x0000000110FDCF00 : 0000 0000 0000 0000 0000 0000 0000 0000
................
0x0000000110FDCF10 : 0000 0000 0000 0000 0000 0000 0000 0000
................
0x0000000110FDCF20 : 0000 0000 0000 0000 0000 0000 0000 0000
................
0x0000000110FDCF30 : 0000 0000 0000 0000 0000 0000 0000 0000
................
0x0000000110FDCF40 : 0000 0000 0000 0000
........

2018-03-30-17.51.04.292095+540 I561101A626          LEVEL:
Warning
PID     : 12345678             TID : 1234           PROC :
db2sysc 0
INSTANCE: e111q1n              NODE : 000           DB   :
SAMPLE
APPHDL  : 0-32                 APPID:
*LOCAL.e111q1n.180330085039
AUTHID  : XXXX              HOSTNAME: 
EDUID   : 3343                 EDUNAME: db2agent (SAMPLE) 0
FUNCTION: DB2 UDB, WLM, sqlrwGetPDDiagHist_v10fp3, probe:200
MESSAGE : ECF=0x9000000C=-1879048180=ECF_INVALID_PARAMETER
          Invalid parameter
DATA #1 : String, 75 bytes
Error initializing the diag log collector. Not able to access
the diag log.


Local bypass:
Make sure starttime is less than endtime when invoke
PD_GET_DIAG_HIST()
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* ALL                                                          *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Db2 11.1 Mod 4 Fixpack 4 or higher                *
****************************************************************
Local Fix:
Solution
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
09.08.2018
27.11.2018
27.11.2018
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)