DB2 - Problem description
Problem IT30675 | Status: Closed |
DB2 CLI/ODBC FAILING WHEN INSERTING THE NULL VALUE TO BOOLEAN DATA TYPE USING PARAMETER MARKER | |
product: | |
DB2 CONNECT / DB2CONNCT / B10 - DB2 | |
Problem description: | |
When doing the array insert on a SQL statement which has boolean column, when one of the boolean column is supplied with SQL_NULL_DATA, CLI is returning [IBM][CLI Driver] CLI0164E Nullable type out of range. SQLSTATE=HY099 | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * DB2 CLI users using boolean column * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 version 11.1.4.6 * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
**************************************************************** * USERS AFFECTED: * * DB2 CLI users using boolean column * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to DB2 version 11.1.4.6 * **************************************************************** | |
Comment | |
DB2 v11.1 M4FP6 contains the fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 23.10.2019 31.03.2021 31.03.2021 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) |