DB2 - Problem description
Problem IT41639 | Status: Closed |
EXCESSIVE DB2DIAG ENTRY FROM SQLPGRETRIEVELOOKUP | |
product: | |
DB2 FOR LUW / DB2FORLUW / B50 - DB2 | |
Problem description: | |
The below diag entry is being printed excessively when there are multiple retrieve requests for the same log file. PID Â Â : 1111 Â Â Â Â Â Â Â Â TID : 111111111111112 PROC : db2sysc 0 INSTANCE: myinst1 Â Â Â Â Â Â Â NODE : 000 Â Â Â Â Â Â DB Â : MYDB HOSTNAME: myhost1 EDUID Â : 61 Â Â Â Â Â Â Â Â Â EDUNAME: db2lfr.0 (MYDB) 0 FUNCTION: DB2 UDB, data protection services, sqlpgRetrieveLookup, probe:500 DATA #1 : Log 12345 on log stream 0 is in the array but is still being retrieved. CALLSTCK: (Static functions may not be resolved correctly, as they are resolved to the nearest symbol) Â [0] 0x000072C24BAE8699 pdLogPrintf + 0x79 Â [1] 0x000072C253E902B5 _Z19sqlpgRetrieveLookupP14sqlpMasterDbcbjmtPm + 0x3A5 Â [2] 0x000072C25401F356 _Z16sqlplfrFMOpenLogP12SQLPLFR_DBCBjP21SQLPLFR_REQ_SCAN_NEXTPmPP 9SQLP_LECB + 0x3DF6 Â [3] 0x000072C2540051D6 _Z16sqlplfrFMReadLogP12SQLPLFR_DBCBP21SQLPLFR_REQ_SCAN_NEXTP17SQ LPLFR_SCAN_DATA + 0x3E6 Â [4] 0x000072C25400A896 _Z17sqlplfrDoScanNextP12SQLPLFR_DBCBP11SQLPLFR_REQ + 0x426 Â [5] 0x000072C25400F2D8 _Z10sqlplfrEduP9sqpLfrEdu + 0x848 Â [6] 0x000072C2541A1B57 _ZN9sqpLfrEdu6RunEDUEv + 0x27 Â [7] 0x000072C255ABE734 _ZN9sqzEDUObj9EDUDriverEv + 0x1A4 Â [8] 0x000072C253D60599 sqloEDUEntry + 0x2A9 Â [9] 0x000072C25A8C3EA5 /lib64/libpthread.so.0 + 0x7EA5 Â [10] 0x000072C2481F29FD clone + 0x6D | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * All * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to 11.5.8. * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
**************************************************************** * USERS AFFECTED: * * All * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to 11.5.8. * **************************************************************** | |
Comment | |
Fixed in 11.5.8, diag entry will no longer be shown at warning level. | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 28.07.2022 30.07.2022 08.09.2022 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) |