Informix - Problem description

Problem IT09485 Status: Closed

IWA: ASSERTION FLUSHEDBLOCKS >= EXPECTEDBLOCKS POSSIBLE WHEN REFRESH
MART IS DONE

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
When you perform a refresh mart operation on a mart which has a 
dimension table on which updates are done you might observe an 
assertion: 
 
(U0001) - error: AQT10050I:  An internal error occurred on the 
'ACC2' accelerator: An assertion 'flushedBlocks >= 
expectedBlocks' failed. Additional info: Wrote 2 new blocks but 
flushed only 1 blocks for table "schemaname"."tab1" 
 
In the message log of the server the Informix Warehouse 
Accelerator is running on you will then find the same assertion 
message: 
 
An assertion 'flushedBlocks >= expectedBlocks' failed. 
Additional info: Wrote 2 new blocks but flushed only 1 blocks 
for table "schemaname"."tab1" 
 
This can happen when the dimension table has a reference tag in 
the mart definition and the Informix Warehouse Accelerator 
instance has been restarted after the last load or refresh of 
the mart. 
 
Once this happens the mart is in a load pending state, a further 
refresh mart attempt will fail because of this mart state and 
the mart needs to be fully loaded again.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* IWA RefreshMart operation after IWA restart with IWA         * 
* configuration number of worker nodes > 1.                    * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Update to IBM Informix Server 12.10.FC6.                     * 
****************************************************************
Local Fix:
Solution
Problem Fixed In IBM Informix Server 12.10.FC6.
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
16.06.2015
30.12.2015
30.12.2015
Problem solved at the following versions (IBM BugInfos)
12.10.FC6
Problem solved according to the fixlist(s) of the following version(s)
12.10.xC6 FixList
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download