Informix - Problem description

Problem IT36873 Status: Closed

IN-PLACE ALTER TABLE CAN LEAD TO A FLOOD OF PAGE OUT-OF-SEQ ERRORS IN
ONLINE.LOG WHEN USING CDC

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
The following was reported on linux x86-64 running IDS
12.10.FC12 and reproduced on same.

This problem can happen on a table that is being captured by CDC
and it has been altered and now has a
couple page versions (confirmed by oncheck -pT).

If you stop CDC full row logging, do an in-place alter on the
table, start CDC full row logging and
then do a small update on the table, you may see a flood of
errors to the online.log that look like:

12:28:05  CDC: Log Seq:  Page out-of-seq error [got page 6:61a4,
cur page 6:b1]
12:28:05  CDC: Log Seq:  Page out-of-seq error [got page 6:61a5,
cur page 6:b1]
12:28:05  CDC: Log Seq:  Page out-of-seq error [got page 6:61a5,
cur page 6:b1]
12:28:05  CDC: Log Seq:  Page out-of-seq error [got page 6:61a6,
cur page 6:b1]
12:28:05  CDC: Log Seq:  Page out-of-seq error [got page 6:61a6,
cur page 6:b1]
12:28:05  CDC: Log Seq:  Page out-of-seq error [got page 6:61a7,
cur page 6:b1]
12:28:05  CDC: Log Seq:  Page out-of-seq error [got page 6:61a7,
cur page 6:b1]

When this starts happening, you will also see a couple dbWorker
threads start using a lot
of cpu as it looks like they get extremely busy processing the
ph_dbs_alert task.

Even when the out-of-seq errors stop being reported, the
dbWorker threads will
remain using high cpu for quite a while.

It seems like you can workaround this problem by resolving the
in-place alter table
before turning full row logging back on.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
* available).                                                  *
****************************************************************
The correct call sequence is:

cdc_endcapture()
cdc_set_fullrowlogging(DISABLE)
Local Fix:
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
* available).                                                  *
****************************************************************
The correct call sequence is:

cdc_endcapture()
cdc_set_fullrowlogging(DISABLE)
Comment
Fixed in Informix Server 12.10.xC15 and 14.10.xC7.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
12.05.2021
23.08.2021
23.08.2021
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
invispix 10x10
invispix 10x10
invispix 10x10
Technical InfoTechnical Info

Technical Info

DocumentationDocumentation

Documentation

IBM NewsletterIBM Newsletter

IBM Newsletter

Current BugsCurrent Bugs

Current Bugs

Bug ResearchBug Research

Bug Research

Bug FixlistsBug Fixlists

Bug Fixlists

Release NotesRelease Notes

Release Notes

Machine NotesMachine Notes

Machine Notes

Release NewsRelease News

Release News

Product LifecycleProduct Lifecycle

Lifecycle

Media DownloadMedia Download

Media Download

invispix 10x10
Service und SupportService und Support

Service and Support

Informix MonitoringInformix Monitoring

Informix Monitoring

Admin-Scout for InformixAdmin-Scout for Informix

Admin-Scout for Informix

Informix News & InfosInformix News & Infos

Informix News & Infos