Informix - Problem description

Problem IT37371 Status: Closed

WRONG TABLE GETTING FRAGMENT ADDED ONCE INSERT COMING FROM TRIGGER HITTING
PARTITION LIMIT

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
Consider a table A with a trigger defined on it and the trigger
inserting into a different table B, now B getting full, so next
insert would have to add a new round-robin fragment (with B
being RR fragmented and AUTOLOCATE on).

What can happen instead, with next activity on A executing the
trigger, is that A is getting a fragment added while B remains
full, and since nothing changed in B, this might even happen
again.
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
* available).                                                  *
****************************************************************
Local Fix:
This might be a transient problem. To completely prevent it,
don't rely on AUTOLOCATE for adding a new round-robin fragment.
Solution
Workaround
****************************************************************
* USERS AFFECTED:                                              *
* Users of Informix Server prior to 12.10.xC15 and 14.10.xC7.  *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* See Error Description                                        *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to Informix Server 12.10.xC15 or 14.10.xC7 (when     *
* available).                                                  *
****************************************************************
Comment
Fixed in Informix Server 12.10.xC15 and 14.10.xC7.
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
22.06.2021
31.08.2021
31.08.2021
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download