Informix - Problem description
Problem IT38357 | Status: Closed |
THREADS CAN REMAIN IN CRITICAL SECTIONS FOR EXTREMELY LONG TIMESDURING LOADS INTO UNLOGGED COMPRESSED TABLES | |
product: | |
INFORMIX SERVER / 5725A3900 / E10 - | |
Problem description: | |
Threads can remain in critical sections for extremely long times during loads into unlogged compressed tables. When this is happening, you will see the thread in a critical section with a stack constantly like: 0x10142d350 oninit :: yield_processor_mvp 0x1013fb518 oninit :: mt_aio_wait 0x100c77e1c oninit :: chunkio_int 0x100c77234 oninit :: chunkio 0x100c7980c oninit :: physio 0x100c706b0 oninit :: buffget 0x100cd2840 oninit :: allocvrow 0x100e951f8 oninit :: wrt_home 0x100e946fc oninit :: wrtrecord 0x100e93ea4 oninit :: rswrite 0x1014f2270 oninit :: fmwrite 0x100577518 oninit :: aud_sqiswrite 0x100789bf8 oninit :: chkrowcons 0x100721e8c oninit :: addone 0x10071d884 oninit :: ins1row 0x10071e04c oninit :: insert_next 0x100790d34 oninit :: doinsert 0x1004583e0 oninit :: excommand 0x100936094 oninit :: sq_execute_workhorse 0x1009365dc oninit :: sq_execute 0x100a06a18 oninit :: sqmain 0x101554388 oninit :: listen_verify 0x1015539bc oninit :: spawn_thread 0x10140f958 oninit :: th_init_initgls 0x10143d104 oninit :: startup | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC16 and 14.10.xC7. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC16 or 14.10.xC7. * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC16 and 14.10.xC7. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC16 or 14.10.xC7. * **************************************************************** | |
Comment | |
Fixed in Informix Server 12.10.xC16 and 14.10.xC7. | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 13.09.2021 02.11.2021 13.06.2023 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) |