Informix - Problem description
Problem IT34056 | Status: Closed |
ONBAR RESTORE FAILED AFTER PSM CATALOG IMPORT | |
product: | |
INFORMIX SERVER / 5725A3900 / E10 - | |
Problem description: | |
Onbar restore failed after psm catalog import with below error: Internal API error ISAM Error = 100. OS Error = 2 (No such file or directory) XBSA Error: (BSACreateObject) A system error occurred. Aborting XBSA session. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 14.10.xC8. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 14.10.xC8. * **************************************************************** | |
Local Fix: | |
Running onpsm -C init deletes the psm catalog and removes the error while restoring. | |
Solution | |
Workaround | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 14.10.xC8. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 14.10.xC8. * **************************************************************** | |
Comment | |
Fixed in Informix Server 14.10.xC8. | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 31.08.2020 07.04.2022 07.04.2022 |
Problem solved at the following versions (IBM BugInfos) | |
Problem solved according to the fixlist(s) of the following version(s) |