Problem IT09187 Status: Closed

RESTORE FAILING WITH "DBSPACE XYZ NOT RECOVERED FROM SAME ARCHIVE
BACKUP AS DBSPACE ROOTDBS" WHEN NO LOGICAL RESTORE IS DONE

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
following error (and hanging ontape -r) while doing cold 
restore: 
 
05/27/15 11:25:40  Physical Restore of rootdbs, logdbs, datadbs, 
datadbs16k, sbspace, s9_sbspc Completed. 
05/27/15 11:25:40  Checkpoint Completed:  duration was 0 
seconds. 
05/27/15 11:25:40  Wed May 27 - loguniq 5, logpos 0x171c018, 
timestamp: 0x3646c Interval: 47 
 
05/27/15 11:25:40  Maximum server connections 0 
05/27/15 11:25:47  No logical log restore will be performed. 
05/27/15 11:25:47  DBspace logdbs not recovered from same 
archive backup as DBspace rootdbs. 
 
05/27/15 11:25:47  Logical restore cannot be skipped. Perform a 
logical restore.    ### !!! 
05/27/15 11:25:47  Cannot change to Quiescent Mode. 
 
ontape -r is than hanging here: 
. 
. 
Continue restore? (y/n)y 
Do you want to back up the logs? (y/n)n 
Using the backup and restore filter /usr/bin/gzip -cd. 
attn: Ignoring unknown or deprecated config parameter 
(OPCACHEMAX) 
Warning: Parameter's user-configured value was adjusted. 
(INFORMIXCONTIME) 
Warning: Parameter's user-configured value was adjusted. 
(GSKIT_VERSION) 
Restore a level 1 archive (y/n) n 
Do you want to restore log tapes? (y/n)n 
/opt/informix/12.10.FC5W1/bin/onmode -sy 
Continue restore? (y/n)y 
Do you want to back up the logs? (y/n)n 
Using the backup and restore filter /usr/bin/gzip -cd. 
attn: Ignoring unknown or deprecated config parameter 
(OPCACHEMAX) 
Warning: Parameter's user-configured value was adjusted. 
(INFORMIXCONTIME) 
Warning: Parameter's user-configured value was adjusted. 
(GSKIT_VERSION) 
Restore a level 1 archive (y/n) n 
Do you want to restore log tapes? (y/n)n 
/opt/informix/12.10.FC5W1/bin/onmode -sy
Problem Summary:
Local Fix:
Solution
Workaround
not known / see Local fix
Comment
This APAR is a duplicate of IT08544
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
29.05.2015
30.12.2015
09.06.2017
Problem solved at the following versions (IBM BugInfos)
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download