Informix - Problem description

Problem IT10729 Status: Closed

DBSCHEMA -SS AND SYSTRIGBODY BOTH REPORT DECIMAL 0 VALUES IN A DIFFERENT
FORMAT THAN CREATE TRIGGER STATEMENT SPECIFIED

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
When creating a trigger with a decimal value 0, the dbschema -ss 
output shows the value 0 in a different format than specified by 
the create trigger statement. 
 
If the create trigger statement specifies the value as 0.00, it 
is listed in the dbschema -ss output and in the systrigbody 
catalog table as "0.". 
 
If the create trigger statement specifies the value as 0, 
without a decimal point, the dbschema -ss output and the 
systrigbody catalog table present it as "0.00". 
 
While this is cosmetic in nature, it makes comparing stored 
procedure and trigger definitions between multiple servers 
difficult, as they will not match.
Problem Summary:
**************************************************************** 
* USERS AFFECTED:                                              * 
* dbschema output of decimal constants in "create trigger"     * 
* statement                                                    * 
**************************************************************** 
* PROBLEM DESCRIPTION:                                         * 
* See Error Description                                        * 
**************************************************************** 
* RECOMMENDATION:                                              * 
* Upgrade to 12.10.xC7 or earlier PID if available             * 
****************************************************************
Local Fix:
Solution
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
17.08.2015
28.06.2016
28.06.2016
Problem solved at the following versions (IBM BugInfos)
12.10.xC7
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download