Informix - Problem description
Problem IT14644 | Status: Closed |
THE PRIMARY SERVER CAN CRASH WITH INVALID MUTEX TYPE WHEN DISCONNECTED WITH RSS SECONDARY SERVER | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
A timing issue between the smxrcv and smxsnd threads can cause smxsnd to remove a pipe that has already been destroyed by the smxrcv thread. The server will fail with Invalid Mutex Type and has the following stack trace: afstack afhandler afcrash_interface mt_lock smx_remove_pipe smx_send_thread th_init_initgls startup | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * informix user with secondary servers * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC7 * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 05.04.2016 29.06.2016 29.06.2016 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC7 | |
Problem solved according to the fixlist(s) of the following version(s) |