Informix - Problem description
Problem IT18480 | Status: Closed |
CONVERT THREAD HANGS WAITING FOR SQLUP CONVERTING TO 12.10.FC8 WHEN THERE IS A TENANT DATABASE | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
Last entry in the online.log: 09:11:06 processing tenantdb Threads: tid tcb rstcb prty status vp-class name 20 45b649f8 44c31f30 3 cond wait sqlup 1cpu convert Stack for thread: 20 convert (oninit) yield_processor_svp (oninit) mt_fast_wait (oninit) wait_sql_online (oninit) rsGetTenantProp (oninit) ddopen (oninit) sql_get_ent_version (oninit) do_each_version_work (oninit) generic_fw_main (oninit) convertSM (oninit) th_init_initgls (oninit) startup | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of an Informix server that contains a tenant database * * and are upgrading to 12.10.xC8. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC9 * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 19.12.2016 10.07.2017 10.07.2017 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC9 | |
Problem solved according to the fixlist(s) of the following version(s) |