Informix - Problem description
Problem IT19760 | Status: Closed |
IFXCLONE CAN CAUSE AN SMX PBACKUP THREAD TO ASSERT FAIL AND BRING THE PRIMARY DOWN | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
The stack trace for the asserting SMX pbackup thread would look like this: 15:01:09 Stack for thread: 7990 SMX pbackup base: 0x000000004910c000 len: 69632 pc: 0x00000000013f4ef7 tos: 0x000000004683c390 state: running vp: 8 afstack mt_ex_throw_sig afsig_handler mt_lock smx_release SC_isopen_arcbu th_init_initgls startup | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * All users using ifxclone could potentially be impacted. * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Update to IBM Informix Server 12.10.xC9 * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 17.03.2017 10.07.2017 10.07.2017 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC9 | |
Problem solved according to the fixlist(s) of the following version(s) |