Informix - Problem description
Problem IT27466 | Status: Closed |
WINDOWS 12.10.TC9 RUNNING ONSMSYNC AS ADMINISTRATOR FAILS TO BUILD IXBAR FILE WITH PERMISSION DENIED | |
product: | |
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10 | |
Problem description: | |
When you run any onsmsync command as Administrator in Windows the ixbar file will fail to be accessed with Permission denied. You will see the same behavior with 'onsmsync -b' but here is bar_act/debug output from running onsmsync -g 1: bar_act.log: 2017-11-15 18:05:01 3876[3544] 3876 onsmsync -g 1 2017-11-15 18:05:01 3876[3544] 3876 Using IBM Corporation's TSM version 5.3.2.0 as the Storage Manager. XBSA API version is 1.0.3. 2017-11-15 18:05:01 3876[3544] 3876 Successfully connected to Storage Manager. 2017-11-15 18:05:03 3876[3544] 3876 Syncing sysutils and bootfile... 2017-11-15 18:05:04 3876[3544] 3876 Successfully connected to Storage Manager. 2017-11-15 18:05:04 3876[3544] 3876 Querying for backups expired at Storage Manager... 2017-11-15 18:05:05 3876[3544] 3876 Building current timeline... 2017-11-15 18:05:05 3876[3544] 3876 Applying expiration policies... 2017-11-15 18:05:06 3876[3544] 3876 Regenerating sysutils and bootfile... 2017-11-15 18:05:06 3876[3544] 3876 (-43050) Copy of old emergency bootfile saved in D:InformixIDSetcixbar.0.20171115.180506 . 2017-11-15 18:05:06 3876[3544] 3876 (-43049) Error writing to the ON-Bar emergency boot file. Before attempting a restore, insert the following into the ON-Bar emergency boot file: sew00vvm003 bapdbs0 ND 0 228 0 0 71683 2017-11-15 18:03:43 1 4659 754453609 228 0 - - 4659 1510787023 1510761754 98 Permission denied 2017-11-15 18:05:06 3876[3544] 3876 onsmsync complete, returning 127 (0x7f) bar_debug.log: 2017-11-15 18:05:06 3876[3544] 3876 boot_write: return 127 (0x7f) 2017-11-15 18:05:06 3876[3544] 3876 bar_regen_bootfile: close s_regen_crs 2017-11-15 18:05:06 3876[3544] 3876 bar_regen_bootfile: free s_regen_stmt 2017-11-15 18:05:06 3876[3544] 3876 boot_close: enter 2017-11-15 18:05:06 3876[3544] 3876 boot_close: input *boot_handle 0x00000005 2017-11-15 18:05:06 3876[3544] 3876 boot_close: output *boot_handle 0xffffffff 2017-11-15 18:05:06 3876[3544] 3876 boot_close: return 0 (0x00) 2017-11-15 18:05:06 3876[3544] 3876 bar_regen_bootfile: return 127 (0x7f) 2017-11-15 18:05:06 3876[3544] 3876 bar_smsync_exec: return 127 (0x7f) 2017-11-15 18:05:06 3876[3544] 3876 barTerminate: enter 2017-11-15 18:05:06 3876[3544] 3876 bar_loadXBSA: return 0 2017-11-15 18:05:06 3876[3544] 3876 barTerminate: return 0 (0x00) 2017-11-15 18:05:06 3876[3544] 3876 onsmsync main: return 127 (0x7f) 2017-11-15 18:05:06 3876[3544] 3876 bar_cleanup: enter 2017-11-15 18:05:06 3876[3544] 3876 bar_srv_status: enter 2017-11-15 18:05:06 3876[3544] 3876 bar_srv_status: return 5 (0x05) The only way to get a new ixbar file is to run an L0 backup. | |
Problem Summary: | |
**************************************************************** * USERS AFFECTED: * * Users of Informix Server prior to 12.10.xC11. * **************************************************************** * PROBLEM DESCRIPTION: * * WINDOWS 12.10.TC9 RUNNING ONSMSYNC AS ADMINISTRATOR FAILS TO * * BUILD IXBAR FILE WITH PERMISSION DENIED * **************************************************************** * RECOMMENDATION: * * Upgrade to Informix Server 12.10.xC11+. * **************************************************************** | |
Local Fix: | |
Solution | |
Workaround | |
not known / see Local fix | |
Timestamps | |
Date - problem reported : Date - problem closed : Date - last modified : | 21.12.2018 04.12.2019 04.12.2019 |
Problem solved at the following versions (IBM BugInfos) | |
12.10.xC11 | |
Problem solved according to the fixlist(s) of the following version(s) |