Informix - Problem description

Problem IT28628 Status: Closed

FAILED CONNECTIONS COULD LEAD TO INCORRECT VALUE FOR SHMEM->SH_RSNACTIVE
WHICH COULD CAUSE PHYSICAL LOG OVERFLOW ASSERTIONS

product:
INFORMIX SERVER / 5725A3900 / C10 - IDS 12.10
Problem description:
Under specific failed connections, it's possible that
shmem->sh_rsnactive will be decremented prior to it having been
incremented.  If this happens often enough
shmem->sh_rsnactive can go to a negative value.  This can lead
to physical log overflow because this value is used in the code
to determine if a non-blocking checkpoint needs to be switched
to a blocking checkpoint, to prevent the physical log from
filling.

The most likely cause of failed connections would be servers
that have SHMTOTAL set to a non-zero value, and the server has
allocated SHMTOTAL amount of memory.

Fixed in 12.10.UC11
Problem Summary:
****************************************************************
* USERS AFFECTED:                                              *
* All operating systems.                                       *
****************************************************************
* PROBLEM DESCRIPTION:                                         *
* Under specific failed connections, it's possible that        *
* shmem->sh_rsnactive will be decremented prior to it having   *
* been                                                         *
* incremented.  If this happens often enough                   *
* shmem->sh_rsnactive can go to a negative value.  This can    *
* lead                                                         *
* to physical log overflow because this value is used in the   *
* code                                                         *
* to determine if a non-blocking checkpoint needs to be        *
* switched                                                     *
* to a blocking checkpoint, to prevent the physical log from   *
* filling.                                                     *
*                                                              *
* The most likely cause of failed connections would be servers *
* that have SHMTOTAL set to a non-zero value, and the server   *
* has                                                          *
* allocated SHMTOTAL amount of memory.                         *
****************************************************************
* RECOMMENDATION:                                              *
* Upgrade to version 12.10.XC11                                *
****************************************************************
Local Fix:
Solution
Workaround
not known / see Local fix
Timestamps
Date  - problem reported    :
Date  - problem closed      :
Date  - last modified       :
01.04.2019
08.10.2019
08.10.2019
Problem solved at the following versions (IBM BugInfos)
12.10.xC11
Problem solved according to the fixlist(s) of the following version(s)
Informix EditionsInformix Editions
Informix Editions
DocumentationDocumentation
Documentation
IBM NewsletterIBM Newsletter
IBM Newsletter
Current BugsCurrent Bugs
Current Bugs
Bug ResearchBug Research
Bug Research
Bug FixlistsBug Fixlists
Bug Fixlists
Release NotesRelease Notes
Release Notes
Machine NotesMachine Notes
Machine Notes
Release NewsRelease News
Release News
Product LifecycleProduct Lifecycle
Lifecycle
Media DownloadMedia Download
Media Download